Nguyễn Duy Sang *

* Tác giả liên hệ (ndsang@ctu.edu.vn)

Abstract

Thermoluminescence (TL) spectra are complex curves that do not adhere the normal distribution but follow the first-, second-, general- order kinetics equations and require a software to analyze. This article presents a method of using R software to fit the empirical and the theoretical curves of the thermoluminescence glow peak types. Thank to this method, characteristic parameters of the trap are also defined such as number of peak, trap depth (E), the order of kinetic(b), the frequency factor (s). The samples spending shorter period of storage time (360h) have smaller kinetic parameter values than the samples spending longer period of storage (720h). Thereby, we can find out the characteristics of the samples which can be applied in the detection of irradiated food, age determination of antiques.
Keywords: Thermoluminescence, kinetic parameters, trap depth, order of kinetic, frequency factor

Tóm tắt

Phổ nhiệt huỳnh quang là một đường cong phức tạp không theo các phân bố thông thường mà tuân theo phương trình động học bậc nhất, bậc hai hoặc bậc tổng quát đòi hỏi một phần mềm để phân tích. Bài báo trình bày phương pháp sử dụng phần mềm R để làm khớp số liệu đường cong thực nghiệm so với đường cong lý thuyết của dạng phổ nhiệt huỳnh quang. Từ phương pháp này, các thông số đặc trưng của bẫy cũng được xác định như số đỉnh, độ sâu bẫy (E), bậc động học (b), hệ số tần số (s). Những mẫu có thời gian bảo quản ngắn (360 h) các thông số động học lớn hơn những mẫu có thời gian bảo quản dài hơn (720h). Qua đó, chúng tôi có thể tìm ra các tính chất đặc trưng của mẫu ứng dụng trong việcdò thực phẩm chiếu xạ, xác định tuổi cho cổ vật.
Từ khóa: Nhiệt huỳnh quang, thông số động học, độ sâu bẫy, bậc động học, hệ số tần số

Article Details

Tài liệu tham khảo

Correcher V., Garcia-Guinea J., 2013 Potential use of the activation energy value calculated from the thermoluminescence glow curves to detect irradiated food. J Radioanal Nucl Chem 298 (2):821-825.

D’Oca M. C., Bartolotta A., Cammilleri C., Giuffrida S., Parlato A., Di Stefano V., 2009 The additive dose method for dose estimation in irradiated oregano by thermoluminescence technique. Food Control 20 (3):304-306.

Dogan T., Toktamis H., Yuksel M., Topaksu M., Yazici A. N., 2015 Thermoluminescence glow curve analysis of natural onyx from Turkey. Appl Radiat Isot 96:13-19.

EN 1788, 2001, Foodstuffs-Thermoluminescence detection of irradiated food from which silicate minerals can be isolated. Brussels: European Committee of Standardization

Horowitz Y. S., Yossian D., 1995 Computerised glow curve deconvolution: application to thermoluminescence dosimetry. Radiat Prot Dosim 60.

Jun Peng, Jorge More, Burton Garbow, Kenneth Hillstrom, John Burkardt, Linda R. Petzold, Alan C. Hindmarsh, Setzer R. W. (2016) Thermoluminescence Glow Curve Deconvolution. http://CRAN.R-project.org/package=tgcd.

Kucuk N., Gozel A. H., Yuksel M., Dogan T., Topaksu M., 2015 Thermoluminescence kinetic parameters of different amount La-doped ZnB2O4. Appl Radiat Isot 104:186.

Pagonis V., Kitis G., Furetta C., 2006, Numerical and Practical Exercises in Thermoluminescence. Springer, United States of America

Pagonis V., Mian S., Kitis G., 2001 Fit of First Order Thermoluminescence Glow Peaks using the Weibull Distribution Function. Radiat Prot Dosim 93 (1):11-17.

Sadek A. M., 2013 Test of the accuracy of the computerized glow curve deconvolution algorithm for the analysis of thermoluminescence glow curves. Nucl instrum meth A 712:56-61.

Sadek A. M., Eissa H. M., Basha A. M., Carinou E., Askounis P., Kitis G., 2015 The deconvolution of thermoluminescence glow-curves using general expressions derived from the one trap-one recombination (OTOR) level model. Appl Radiat Isot 95:214-221.

Nguyễn Duy Sang, 2015, Đo phổ nhiệt huỳnh quang của bột ớt với các liều chiếu xạ khác nhau, Tạp chí Khoa học Trường Đại học Sư Phạm TP. Hồ Chí Minh, số 9 (75).

Nguyễn Duy Sang, 2013, Nghiên cứu ứng dụng hiện tượng nhiệt huỳnh quang trong việc xác định sản phẩm chiếu xạ ở Việt Nam, Tạp chí Khoa học Trường Đại học Cần Thơ, số 29, tr. 105-110.